¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹³»ÇмúÁö³í¹®

Á¦¸ñ
(2012) Analysis of the Disease Spread in a Livestock Building Using Tracer Gas Experiment
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
120


(2012) ÃßÀû°¡½º ½ÇÇèÀ» ÅëÇÑ Ãà»ç ³» Áúº´ È®»ê ºÐ¼®
Analysis of the Disease Spread in a Livestock Building Using Tracer Gas Experiment
 

ÇÐȸÁö: Çѱ¹³ó°øÇÐȸ³í¹®Áý 54(3), 37 - 45ÂÊ.
 
ÀúÀÚ: ¼Û»óÇö, ÀÌÀκ¹, ±Ç°æ¼®, ÇÏÅÂȯ, J. P. Bitog, È«¼¼¿î, ¼­ÀÏȯ, ¹®¿î°æ, ±è¿¬ÁÖ, ÃÖÀºÁø
 
°³¿ä
Recently, the livestock industry in Korea was heavily affected by the outbreak of official livestock diseases such as foot and mouse disease, high pathogenic avian influenza, swine influenza, and so on. It has been established that these diseases are being spread through direct contact, droplet and airborne transmission. Among these transmissions, airborne transmission is very complex in conducting field investigation due to the invisibility of the pathogens and unstable weather conditions. In this study, the airborne transmission was thoroughly investigated inside a pig house by conducting tracer gas (CO2) experiment because experiment with real pathogen is limited and dangerous. This is possible as it can be assumed that the flow is similar pattern very fine particles and gas. In the experiment, the ventilation structure as well as the location of gas emission were varied. The CO2 detection sensors were installed at 0.5 and 1.3 m height from the floor surface. The tracer gas level was measured every second. Results revealed that the direction of spread can be determined by the response time. Response time refers to the time to reach 150 ppm from the gas emission source at each measuring points. The location of the main flow as well as the gas emission was also found to be very important factor causing the spread.

 
 
Download Link :
https://www.researchgate.net/profile/Jessie_Pascual_Bitog/publication/263644324_Analysis_of_the_Disease_
Spread_in_a_Livestock_Building_Using_Tracer_Gas_Experiment/links/540f23a60cf2df04e75a2646.pdf



 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2012) Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House
/ A3EL
(2012) °­Á¦ ȯ±â½Ä À°°è»ç ´ÙÁß ÀԱ⠽½·Ô¿¡¼­ÀÇ ÀÔ±â·ù µµ´Þ°Å¸® ºÐ¼® Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House ÇÐȸÁö:Çѱ¹³ó°øÇÐȸ³í¹®Áý 54(2), 55 -65ÂÊ. ÀúÀÚ:±Ç°æ¼®, ÇÏÅÂȯ, ÀÌÀκ¹, È«¼¼¿î, ¼­ÀÏȯ, Jessie P. Bitog °³¿ä In the winter sea..
ÀÌÀü±Û
(2012) Evaluation and CFD Modelling of Flow behind Livestock Ventilation Fan for Small-Scale Wind Power Generation
/ A3EL
(2012) Ãà»ç ȯ±âÆÒ ÈÄ·ùÀÇ Ç³¿¡³ÊÁö Æò°¡ ¹× ±â·ù Çü»óÀÇ Àü»êÀ¯Ã¼¿ªÇÐ ¸ðµ¨¸µ Evaluation and CFD Modelling of Flow behind Livestock Ventilation Fan for Small-Scale Wind Power Generation ÇÐȸÁö:Çѱ¹³ó°øÇÐȸ³í¹®Áý 54(5), 79 - 89ÂÊ. ÀúÀÚ:È«¼¼¿î, ÀÌÀκ¹, ¼­ÀÏȯ, ±Ç°æ¼®, ÇÏÅÂȯ, ȲÇö¼·. °³¿ä The ..