¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹Á¦ÇмúÁö³í¹®

Á¦¸ñ
(2022) Air conditioning system design to reduce condensation in an underground utility tunnel using CFD
ÀÛ¼ºÀÏ
2022-11-08
Á¶È¸¼ö
252


(2022) Air conditioning system design to reduce condensation in an underground utility tunnel using CFD


Journal : IEEE ACCESS : PRACTICAL RESEARCH, OPEN SOLUTIONS (2022), 1-1

Author :  Se-Jun Park, In-Bok Lee*, Sang-Yeon Lee, Jun-Gyu Kim, Jeong-Hwa Cho,  Cristina Decano, Young-Bae Choi, Min-Hyung Lee, Hyo-Hyeog Jeong, Uk-Hyeon Yeo, Woo-Sug Jung, Deuk-Young Jeong

Abstract
 
In this study, the internal environment such as the air temperature, humidity, and wall temperature of the underground utility tunnel, was analyzed. The current status and problems of the air conditioning system were examined by analyzing the capacity of the exhaust fan and the air velocity inside the utility tunnel. The field experiment showed that the utility tunnel has a relative humidity of 95% or higher for most sections during summer. The deviation of the internal air temperature was about 4 ¡É depending on the section, and the dew condensation occurred. However, most of the exhaust fans has a capacity below the standard minimum air velocity of 2.5m·s-1. In particular, in the section where dew condensation occurred, the air velocity was 0.26 to 0.97 m·s-1, indicating the presence of stagnant air inside the facility. Therefore, this study attempted to minimize dew condensation by calculating the proper exhaust fan capacity using computational fluid dynamics and installing circulation fans and duct systems in the section where the dew condensation occurred. As a result, when a circulation fan was installed, it was possible to increase the air velocity inside the utility tunnel, and the relative humidity could be reduced by about 78%. By installing a duct, the direct supply of external air or the discharge of internal humid air was simulated for the section where dew condensation occurred. The result showed that the relative humidity could be reduced by about 78% when the duct system was operated in the intake direction.

Keywords :  Condensation, CFD, Circulation fan, Duct, Ventilation, Underground utility tunnel
 
Download Link :  10.1109/ACCESS.2022.3219210
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2023) Estimation of ventilation rate in a piglet house considering ventilation system characteristics
/ A3EL
(2023)Estimation of ventilation rate in a piglet house considering ventilation system characteristics Journal: Biosystems Engineering227(2023), 1-18 Author: Young-Bae Choi, Jun-Gyu Kim, Jeong-Hwa Cho,Sang-Yeon Lee, Se-Jun Park, Cristina Decano-Valentin, Deuk-Young Jeong, In-Bok Lee* Abstr..
ÀÌÀü±Û
(2022) Analysis of local mean age and air supply effectiveness in a piglet house using the tracer gas decay method
/ A3EL
(2022) Analysis of local mean age and air supply effectiveness in a piglet house using the tracer gas decay method Journal:Biosystems Engineering 224(2022), 49-67 Author:Jun-Gyu Kim, In-Bok Lee*, Rack-Woo Kim, Uk-Hyeon Yeo, Sang-Yeon Lee, Deuk-Young Jeong, Cristina Decano Abstract The ve..