¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹Á¦ÇмúÁö³í¹®

Á¦¸ñ
(2022) Analysis of local mean age and air supply effectiveness in a piglet house using the tracer gas decay method
ÀÛ¼ºÀÏ
2022-10-19
Á¶È¸¼ö
162


(2022) Analysis of local mean age and air supply effectiveness in a piglet house using the tracer gas decay method

Journal : Biosystems Engineering 224(2022), 49-67

Author :  Jun-Gyu Kim, In-Bok Lee*, Rack-Woo Kim, Uk-Hyeon Yeo, Sang-Yeon Lee, Deuk-Young Jeong, Cristina Decano

Abstract
 
The ventilation efficiency of an artificially controlled experimental piglet house was evaluated using the tracer gas decay (TGD) method, which can predict the airflow pattern by tracking the tracer gas. The ventilation rate of the exhausted fan was classified as 120, 80, and 40 m3 min−1. Three inlet types were used as follows: (1) side windows, (2) ceiling slot with opening angle of 90°, and (3) ceiling slot with opening angle of 45°. Then, the local mean age (LMA) and air supply effectiveness (ASE) were calculated from the measured data at 18 points (3 × 3 sensors placed top and bottom). The LMA means the time for the inflow air to reach a point and ASE is the ratio of the LMA at a point to the total average LMA in the facility. When side windows and ceiling slots were used with the ventilation rate of 120 m3 min−1, each ASE was approximately 0.8 and 0.9, respectively, suggesting that ceiling slots could be more efficient than side windows with high ventilation rate. When the ventilation rate was low, the ASE of side windows was higher than the ceiling slots. However, when the angle of ceiling slots was changed to 45° with the ventilation rate of 40 m3 min−1, the ASE was almost 1.0, indicating that the ventilation efficiency was improved. Thus, ventilation efficiency can be sufficiently improved for all ventilation rates by using ceiling slots whilst controlling the angle of the slots.

Keywords  air supply effectiveness, artificial piglet house, local mean age, tracer gas decay method, ventilation efficiency
 
Download Link :  https://doi.org/10.1016/j.biosystemseng.2022.09.004
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2022) Air conditioning system design to reduce condensation in an underground utility tunnel using CFD
/ A3EL
(2022)Air conditioning system design to reduce condensation in an underground utility tunnel using CFD Journal:IEEE ACCESS : PRACTICAL RESEARCH, OPEN SOLUTIONS(2022), 1-1 Author: Se-Jun Park, In-Bok Lee*, Sang-Yeon Lee, Jun-Gyu Kim, Jeong-Hwa Cho, Cristina Decano, Young-Bae Choi, Min-Hyung L..
ÀÌÀü±Û
(2022) Development of an Air-Recirculated Ventilation System for a Piglet House, Part 2: Determination of the Optimal Module Combination Using the Numerical Model
/ A3EL
(2022) Development of an Air-Recirculated Ventilation System for a Piglet House, Part 2: Determination of the Optimal Module Combination Using the Numerical Model Journal:agriculture 2022, 12(10), 1533 Author:Jun-Gyu Kim, In-Bok Lee*, Sang-Yeon Lee, Deuk-Young Jeong, Young-Bae Choi, Jeong-Hwa ..