¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹Á¦ÇмúÁö³í¹®

Á¦¸ñ
(2021) Dynamic Energy Exchange Modelling for a Plastic-Covered Multi-Span Greenhouse Utilizing a Thermal Effluent from Power Plant
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
215


(2021) Dynamic Energy Exchange Modelling for a Plastic-Covered Multi-Span Greenhouse Utilizing a Thermal Effluent from Power Plant


 
Journal : Agronomy 2021, 11(8), 1461
 
Author Sang-Yeon Lee, In-Bok Lee*, Seung-no Lee, Uk-Hyeon Yeo,  Jun-Gyu Kim, Rack-woo Kim, Cristina Decano-Valentin
 
 

Abstract

To utilize the energy in the thermal effluent, many attempts have been made to use the thermal effluent for agricultural facilities such as greenhouses. As the first step, it is important to estimate the energy loads of the greenhouse for deciding a suitable scale for the heating and cooling. Then, it is available to estimate the energy efficiency of the thermal effluent heat pump system installed in the greenhouse. Therefore, the main objectives of this study were to design and validate an energy model of the experimental greenhouse growing Irwin mangoes and to estimate the annual and maximum energy loads using building energy simulation (BES). Field experiments were conducted in a multi-span plastic-covered greenhouse growing Irwin mangoes to measure the internal environments of the greenhouse and crop characteristics. The energy exchange model of the greenhouse considering crop, cladding, heat pump was developed using BES. The BES model was validated using the data measured at field experiments. The designed model was found to be able to provide satisfactory estimates of the changes of the internal air temperature of the greenhouse (R2 = 0.94 and d = 0.97). The hourly energy loads computed by using the validated model were used to analyse the periodic and maximum energy loads according to the growth stage of the cultivated crops. Finally, the energy costs were compared according to the type of energy source based on the calculated annual energy loads. The average energy cost when using the thermal effluent—heat pump system was found to be 68.21% lower than that when a kerosene boiler was used.

Keywords : crop energy exchange; dynamic energy model; greenhouse; information and communication technology; thermal effluent



Download Link : https://doi.org/10.3390/agronomy11081461
 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2021) Integrated Building Energy Simulation–Life Cycle Assessment (BES–LCA) Approach for Environmental Assessment of Agricultural Building: A Review and Application to Greenhouse Heating Systems
/ A3EL
(2021)Integrated Building Energy Simulation–Life Cycle Assessment (BES–LCA) Approach for Environmental Assessment of Agricultural Building: A Review and Application to Greenhouse Heating Systems Journal:Agronomy2021,11(6), 1230 Author:Cristina Decano-Valentin,In-Bok Lee*,Uk-Hyeon..
ÀÌÀü±Û
(2021) Computational Fluid Dynamics Modelling of the Microclimate within the Boundary Layer of Leaves Leading to Improved Pest Control Management and Low-Input Greenhouse
/ A3EL
(2021) Computational Fluid Dynamics Modelling of the Microclimatewithin the Boundary Layer of Leaves Leading to Improved PestControl Management and Low-Input Greenhouse Journal:Sustainability2021,13(15), 8310 Author:Hicham Fatnassi*, Thierry Boulard, Christine Poncet, Nikolaos Katsoulas, T..