(2020) Dynamic energy modelling for analysis of the thermal and hygroscopic environment in a mechanically ventilated duck house
 
Journal : BIOSYSTEMS ENGINEERING, 200, 431~449
 
Author Sang-Yeon Lee, In-Bok Lee*, Rack-Woo Kim, Uk-Hyeon Yeo, Jun-Gyu Kim, Kyeng-seok Kwon
 
 

Abstract

Thermal and hygroscopic environments inside a duck house are two of the most important factors directly related to their productivity and energy costs. However, few quantitative analyses of these environments have been performed. The objective of this study was to develop a dynamic energy model for the combined and real-time quantitative analysis of thermal and hygroscopic environments inside a mechanically ventilated duck house. To identify seasonal problems and develop the energy model, the internal and external environments of the duck house were first monitored via field experiments. Additionally, chamber experiments were conducted in a temperature- and humidity-controlled chamber to calculate the amount of evaporation from duck-house litter for incorporation of these data into the energy model. According to the environmental data measured in the field experiments and the results of the chamber experiments, the dynamic energy model of the duck house was developed using building energy simulation (BES). The BES model was validated by comparison of the BES-computed and field-measured data of the air temperature and relative humidity. The results showed errors of 1.71% and 4.33% for the air temperature and relative humidity, respectively. Finally, the validated BES model of the duck house was used to analyse the seasonal periodic and maximum energy loads. Furthermore, the high-temperature stress of the ducks in summer was also estimated for different space allowances.

Keywords : Building Energy Simulation, Chamber experiment, Duck house, Dynamic energy model, Environmental monitoring



Download Link : https://doi.org/10.1016/j.biosystemseng.2020.10.015
 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2020) Impact Analysis of Environmental Conditions on Odour Dispersion Emitted from Pig House with Complex Terrain Using CFD
/ A3EL
(2020)Impact Analysis of Environmental Conditions on Odour Dispersion Emitted from Pig House with Complex Terrain Using CFD Journal:AGRONOMY, 10(11) Author:Uk-Hyeon Yeo; Cristina Decano-Valentin; Taehwan Ha*; In-Bok Lee; Rack-Woo Kim; Sang-Yeon Lee;Jun-Gyu Kim Abstract With the rise in..
ÀÌÀü±Û
(2019) Computational fluid dynamics evaluation of pig house ventilation systems for improving the internal rearing environment
/ A3EL
(2019) Computational fluid dynamics evaluation of pig house ventilation systems for improving the internal rearing environment Journal: Biosystems Engineering, 186, 259-278 Author: Uk-Hyeon Yeo , In-Bok Lee*, Rack-Woo Kim, Sang-Yeon Lee, Jun-Gyu Kim Abstract Due to the cold stress experien..