(2019) Evaluation of various national greenhouse design standards for wind loading
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
108


(2019) Evaluation of various national greenhouse design
standards for wind loading
 
Journal : Biosystems Engineering, 188, 136-154
 
Author : Rack-woo Kim, In-bok Lee*, Uk-hyeon Yeo, Sang-yeon Lee
 
Abstract


The greenhouse design standard for South Korea is under revision to ensure the structural
safety of greenhouses in response to strong winds. In order to ensure that suitable design
standards for structural safety are adopted, wind load criteria for a range of countries have
been analysed. The provisions for wind load, correction factors, and wind pressure coefficients
were analysed using greenhouse design standards from Korea, China, Japan,
United States of America (USA), and European Union (EU) (CEN, 2001; JGHA, 2016; MAFRA,
1999; MOHURD, 2017; NGMA, 2004). Although the calculations are similar throughout these
greenhouse design standards (CEN, 2001; JGHA, 2016; MAFRA, 1999; MOHURD, 2017; NGMA,
2004), different factors are used to calculate wind load. From the analysed data, a structural
analysis was conducted to evaluate the structural safety of the designs for wind load. The
results indicated that a relatively rigid member should be used for a greenhouse framework
constructed using the greenhouse design standard from USA (NGMA, 2004) and that a
relatively inexpensive greenhouse could be constructed using the greenhouse design

standard from Japan (JGHA, 2016). 


Keywords : Greenhouse/ Greenhouse design standard/ Wind load
Download Link : https://doi.org/10.1016/j.biosystemseng.2019.10.004

 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2019) Estimating the wind pressure coefficient for singlespan greenhouses using an large eddy simulation turbulence model
/ A3EL
(2019)Estimating the wind pressure coefficient for singlespan greenhouses using an large eddy simulationturbulence model Journal: Biosystems Engineering , 188, 114-135 Author: Rack-woo Kim, In-bok Lee*, Uk-hyeon Yeo, Sang-yeon Lee Abstract The wind pressure coefficient (Cp) can be d..
ÀÌÀü±Û
(2019) Development of a VR simulator for educating CFD-computed internal environment of piglet house
/ A3EL
(2019)Development of a VR simulator for educating CFD-computed internal environment of piglet house Journal: Biosystems Engineering, 188, 243-264 Author:Rack-woo Kim,Jun-gyuKim,In-bok Lee*, Uk-hyeon Yeo, Sang-yeon Lee Abstract In terms of maintaining an optimum micro-climates in livest..