(2012) Computational fluid dynamics simulation of air temperature distribution inside broiler building fitted with duct ventilation system
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
96


(2012) Computational fluid dynamics simulation of air temperature distribution inside broiler building fitted with duct ventilation system
 
Journal: biosystems engineering 112, pp.293 - 303.
 
Author: Ehab Mostafa, In-Bok Lee, Sang-Hyeon Song, Kyeong-Seok Kwon, Il-Hwan Seo, Se-Woon Hong,
 Hyun-Seob Hwang, Jessie Pascual Bitog, Hwa-Taek Han
 
Abstract
An investigation was conducted to develop ventilation systems to prevent cold air drafts during the winter season and create a suitable atmosphere inside the broiler rearing building. In the cold weather, ventilation ducts and low ventilation rates are used to maintain the required air temperature. Perforated ducts are preferred for heating spaces because they provide efficient and uniform distribution of the entire air volume. Four ventilation systems were designed in order to establish a comfortable zone for the broilers during winter season. To investigate these different systems under realistic conditions, computational fluid dynamic simulation was used. Field experiments were conducted to validate the designed cases. From the validation results, very low errors were observed. The improved designs were compared with the standard design in terms of ventilation rate, air temperature distribution and indoor gas concentration reduction. Case four (C-4) of the improved designs achieved the highest ventilation rate in the broiler zone. In C-4, theinlet duct was installed in building side and the outlet duct in the opposite side. It achieved about 54% of the ventilation in comparison to standard design. All improved designs showed high uniformity ranging around 60e70% compared to the standard design. For gas dilution in broiler zone, C-4 showed 15% ammonia reduction efficiency 3 min after operating the ventilator.



Keywords: -


Download Link :

https://doi.org/10.1016/j.biosystemseng.2012.05.001


 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2012) Numerical simulation study of a tree windbreak
/ A3EL
(2012) Numerical simulation study of a tree windbreak Journal:biosystems engineering 111, pp.40 - 48. Author:Jessie P. Bitog, In-Bok Lee, Hyun-Seob Hwang, Myeong-Ho Shin, Se-Woon Hong, Il-Hwan Seo, Kyeong-Seok Kwon, Ehab Mostafa, Zhenzhen Pang Abstract In this study, computational fluid d..
ÀÌÀü±Û
(2012) Modelling of internal environmental conditions in a full-scale commercial pig house containing animals
/ A3EL
(2012) Modelling of internal environmental conditions in a full-scale commercial pig house containing animals Journal:biosystems engineering 111, pp.91 - 106. Author:Il-hwan Seo, In-bok Lee, Oun-kyeong Moon, Se-woon Hong, Hyun-seob Hwang, Jessie P. Bitog, Kyeong-seok Kwon, Zhangying Ye, Jong-w..