±¹³»ÇмúÁö³í¹®
(2017) BES¸¦ ÀÌ¿ëÇÑ ¿¬µ¿Çü ¿Â½ÇÀÇ ³Ã·³¹æ ºÎÇÏ »êÁ¤ ¹× PV ½Ã½ºÅÛ ¹ßÀü ¼º´É ºÐ¼®
Estimation on Heating and Cooling Loads for a Multi-Span Greenhouse and Performance Analysis of PV System using Building Energy Simulation
ÇÐȸÁö: ½Ã¼³¿ø¿¹ ½Ä¹°°øÀå 26(4) 258 - 267 ÂÊ
ÀúÀÚ: À̹ÎÇü, ÀÌÀκ¹, ÇÏÅÂȯ, ±è¶ô¿ì, ¿©¿íÇö, ÀÌ»ó¿¬, ¹Ú°ü¿ë, ±èÁرÔ
°³¿ä
The price competitiveness of photovoltaic system (PV system) has risen recently due to the growth of industries, however, it is rarely applied to the greenhouse compared to other renewable energy. In order to evaluate the application of PV system in the greenhouse, power generation and optimal installation area of PV panels should be analyzed. For this purpose, the prediction of the heating and cooling loads of the greenhouse is necessary at first. Therefore, periodic and maximum energy loads of a multi-span greenhouse were estimated using Building Energy Simulation(BES) and optimal installation area of PV panels was derived in this study. 5 parameter equivalent circuit model was applied to analyzed power generation of PV system under different installation angle and the optimal installation condition of the PV system was derived. As a result of the energy simulation, the average cooling load and heating load of the greenhouse were 627,516MJ and 1,652,050MJ respectively when the ventilation rate was 60AE·hr-1. The highest electric power production of the PV system was generated when the installation angle was set to 30o. Also, adjustable PV system produced about 6% more electric power than the fixed PV system. Optimal installation area of the PV panels was derived with consideration of the estimated energy loads. As a result, optimal installation area of PV panels for fixed PV system and adjustable PV system were 521m2 and 494m2 respectively.
Download Link :
http://www.dbpia.co.kr/Journal/ArticleDetail/NODE07257486
QUICK
MENU
TOP