¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹³»ÇмúÁö³í¹®

Á¦¸ñ
(2017) Development of CFD model for Predicting Ventilation Rate based on Age of Air Theory using Thermal Distribution Data in Pig House
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
182


(2017) µ·»ç ³»ºÎ ¿­È¯°æ ºÐÆ÷ÀÇ °ø±â¿¬·É À̷йý Àû¿ëÀ» ÅëÇÑ Àü»êÀ¯Ã¼¿ªÇРȯ±â ¿¹Ãø ¸ðµ¨ °³¹ß
Development of CFD model for Predicting Ventilation Rate based on Age of Air Theory using Thermal Distribution Data in Pig House

ÇÐȸÁö: Çѱ¹³ó°øÇÐȸ 59(6) 51 - 61 ÂÊ


ÀúÀÚ: ±è¶ô¿ì, ÀÌÀκ¹, ÇÏÅÂȯ,  ¿©¿íÇö, ÀÌ»ó¿¬, À̹ÎÇü, ¹Ú°ü¿ë, ±èÁرÔ

°³¿ä


 The tracer gas method has an advantage that can estimate total and local ventilation rate by tracing air flow. However, the field measurement using tracer gas has disadvantages such as danger, inefficiency, and high cost. Therefore, the aim of this study was to evaluate ventilation rate in pig house by using the thermal distribution data rather than tracer gas. Especially, LMA (Local Mean Age), which is an index based on the age of air theory, was used to evaluate the ventilation rate in pig house. Firstly, the field experiment was conducted to measure micro-climate inside pig house, such as the air temperature, CO2 concentration and wind velocity. And then, LMA was calculated based on the decay of CO2 concentration and air temperature, respectively. This study compared between LMA determined by CO2 concentration and air temperature; the average error and root mean square error were 3.76 s and 5.34 s. From these results, it was determined that thermal distribution data could be used for estimation of LMA. Finally, CFD
(Computational fluid dynamic) model was validated using LMA and wind velocity. The mesh size was designed to be 0.1 m based on the grid independence test, and the Standard k-
ω model was eventually chosen as the proper turbulence model. The developed CFD model was highly appropriate for evaluating the ventilation rate in pig house.
 

 
 
Download Link :
https://doi.org/10.5389/KSAE.2017.59.6.061
https://www.koreascience.or.kr/article/JAKO201734963727060.page



 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2017) Estimation on Heating and Cooling Loads for a Multi-Span Greenhouse and Performance Analysis of PV System using Building Energy Simulation
/ A3EL
(2017) BES¸¦ ÀÌ¿ëÇÑ ¿¬µ¿Çü ¿Â½ÇÀÇ ³Ã·³­¹æ ºÎÇÏ »êÁ¤ ¹× PV ½Ã½ºÅÛ ¹ßÀü ¼º´É ºÐ¼® Estimation on Heating and Cooling Loads for a Multi-Span Greenhouse and Performance Analysis of PV System using Building Energy Simulation ÇÐȸÁö: ½Ã¼³¿ø¿¹ ½Ä¹°°øÀå 26(4) 258 - 267 ÂÊ ÀúÀÚ: À̹ÎÇü, ÀÌÀκ¹..
ÀÌÀü±Û
(2017) A Study on the Trends of Virtual Reality Application Technology for Agricultural Education
/ A3EL
(2017) °¡»óÇö½Ç ÀÀ¿ë±â¼úÀÇ µ¿Ç⠺м®À» ÅëÇÑ ±¹³» ½Ã¼³³ó¾÷ÀÇ ±³À°¿ë °¡»óÇö½Ç È°¿ë¹æ¾È A Study on the Trends of Virtual Reality Application Technology for Agricultural Education ÇÐȸÁö: Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ 27(2) 147-157 ÂÊ ÀúÀÚ: ±èÁرÔ, ÀÌÀκ¹, À±±¤½Ä, ÇÏÅÂȯ, ±è¶ô¿ì, ¿©¿íÇö, ÀÌ»ó¿¬ °³¿ä ..