바로가기 메뉴

바로가기 메뉴 본문내용 바로가기 메인메뉴 바로가기

주요안내

HOME 사이트맵 ENGLISH

FONT SIZE

폰트크기 키움 100% 110% 120% 130% 140% 폰트크기 줄임
메뉴보기

국제학술지논문

제목
(2009) Improvement of the ventilation system of a naturally ventilated broiler house in the cold season using computational simulations
작성일
2022-01-10
조회수
204


(2009) Improvement of the ventilation system of a naturally ventilated broiler house in the cold season using computational simulations
 
Journal: Biosystems Engineering 104, pp.106 – 117.
 
Author: I.-H. Seo, I.-B. Lee, O.-K. Moon, H.-T. Kim, H.-S. Hwang, S.-W. Hong, J.P. Bitog,
J.-I. Yoo, K.-S. Kwon, Y.-H. Kim, J.-W. Han
 
Abstract
Limited measurement points and unpredictable airflows, as well as uncontrollable weather conditions, make conducting field experiments to study ventilation in broiler houses very difficult. Simulations using computational fluid dynamics (CFD) are often used to overcome the above mentioned limitation. In this study, airflow, internal air temperature distribution and ventilation efficiency of a conventional ventilation system and several modified ventilation systems were analysed both quantitatively and qualitatively using a previously developed CFD model. These analyses were conducted in order to enhance the rearing condition of the conventional, natural ventilated broiler houses. A tracer gas decay method was adapted to the CFD main solver utilising a user-defined function to calculate the ventilation efficiency and building energy simulation (BES) method was used to compute the heating load. In order to replicate the ventilation problems encountered during the field experiment, the various ventilation systems were studied in the cold season with four different types of vent openings: a chimney, a side vent, a pipe under the roof and a side-up vent at the eaves. From the CFD results, the optimum results were obtained with a model that used a diffuser beneath the chimney inlet which mixed the incoming cold air with the warm air that had accumulated in the upper portion of the broiler house.An additional curtain installed close to the internal side wall effectively guided exhaust gas to the outlet vents and introduced the incoming fresh air to the broiler zone. The curtain also enhanced the thermal insulation at the side wall. Because of its high ventilation efficiency in the broiler zone, compared with a conventional broiler house there was a 32% increase in the thermal uniformity and a 14% increase in the thermal suitability. The BES results indicated that the model could save 47% of the energy input at the broiler zone compared to the conventional ventilation system. An additional field experiment demonstrated that an upgraded broiler house adapted to the model saved 30%of energy costs.



Keywords: -

Download Link :

https://doi.org/10.1016/j.biosystemseng.2009.05.007


 
첨부파일:
첨부파일이 없습니다.
다음글
(2009) Ventilation design for a chick incubator using computational fluid dynamics
/ A3EL
(2009) Ventilation design for a chick incubator using computational fluid dynamics Journal:JARQ 43(3), pp.227–237. Author:In-bok LEE, Sadanori SASE, Hwa-taek HAN, Hi-ki HONG, Si-heung SUNG, Hyun-sub HWANG, Se-woon HONG, Il-hwan SEO and Soon-Hong KWON Abstract We used aerodynamic tech..
이전글
(2009) Airflow characteristics at the surface of manure in a storage pit affected by ventilation rate, floor slat opening, and headspace height
/ A3EL
(2009) Airflow characteristics at the surface of manure in a storage pit affected by ventilation rate, floor slat opening, and headspace height Journal:Biosystems Engineering 104(1), pp.1−9. Author:Z. Ye, G. Zhang, I.-H. Seo, P. Kai, C.K. Saha, C. Wang, B. Li Abstract To inform the m..