¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹³»ÇмúÁö³í¹®

Á¦¸ñ
(2016) Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
192


(2016) °Ç¹°¿¡³ÊÁö½Ã¹Ä·¹À̼ÇÀ» È°¿ëÇÑ ¿¬µ¿Çü ¿Â½Ç ¹× ÀÛ¹°¿¡³ÊÁö¸ðµ¨ ¼³°è ¹× ÀÌÀÇ ³Ã·³­¹æºÎÇÏ »êÁ¤
Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation

ÇÐȸÁö: ½Ã¼³¿ø¿¹·½Ä¹°°øÀå 25(2) 123 - 132 ÂÊ


ÀúÀÚ: À̽³ë, ¹Ú¼¼ÁØ, ÀÌÀκ¹, ÇÏÅÂȯ, ±Ç°æ¼®, ±è¶ô¿ì, ¿©¿íÇö, ÀÌ»ó¿¬


°³¿ä


The importance of energy saving technology for managing greenhouse was recently highlighted. For practical use of energy in greenhouse, it is necessary to simulate energy flow precisely and estimate heating/cooling loads of greenhouse. So the main purpose of this study was to develope and to validate greenhouse energy model and to estimate annual/maximum energy loads using Building Energy Simulation (BES). Field experiments were carried out in a multi-span plastic-film greenhouse in Jeju Island (33.2°N, 126.3°E) for 2 months. To develop energy model of the greenhouse, a set of sensors was used to measure the greenhouse microclimate such as air temperature, humidity, leaf temperature, solar radiation, carbon dioxide concentration and so on. Moreover, characteristic length of plant leaf, leaf area index and diffuse non-interceptance were utilized to calculate sensible and latent heat exchange of plant. The internal temperature of greenhouse was compared to validate the greenhouse energy model. Developed model provided a good estimation for the internal temperature throughout the experiments period (coefficients of determination > 0.85, index of agreement > 0.92). After the model validation, we used last 10 years weather data to calculate energy loads of greenhouse according to growth stage of greenhouse crop. The tendency of heating/cooling loads change was depends on external weather condition and optimal temperature for growing crops at each stage. In addition, maximum heating/cooling loads of reference greenhouse were estimated to 644,014 and 756,456 kJ·hr-1, respectively.
 

 
 
Download Link :
https://www.researchgate.net/profile/I-B_Lee/publication/309599922_Design_of_Energy_Model_of_Greenhouse_Including_Plant_and_Estimation_of_Heating_and_Cooling_Loads_for_a_Multi-Span_Plastic-Film_Greenhouse_by_Building_Energy_Simulation/links/584112fb08aeda696812dc88/Design-of-Energy-Model-of-Greenhouse-Including-Plant-and-Estimation-of-Heating-and-Cooling-Loads-for-a-Multi-Span-Plastic-Film-Greenhouse-by-Building-Energy-Simulation.pdf


 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2016) Analysis of Research Trend and Core TechnologiesBased on ICT to Materialize Smart-farm
/ A3EL
(2016) ½º¸¶Æ®ÆÊ ±¸ÇöÀ» À§ÇÑ ¿¬±¸µ¿Çâ ¹× ICT Çٽɱâ¼ú ºÐ¼® Analysis of Research Trend and Core TechnologiesBased on ICT to Materialize Smart-farm ÇÐȸÁö: ½Ã¼³¿ø¿¹·½Ä¹°°øÀå 25(1) 30 - 41 ÂÊ ÀúÀÚ: ¿©¿íÇö, ÀÌÀκ¹, ±Ç°æ¼®, ÇÏÅÂȯ, ¹Ú¼¼ÁØ, ±è¶ô¿ì, ÀÌ»ó¿¬ °³¿ä Korean government ha..
ÀÌÀü±Û
(2015) Analysis of Ventilation Efficiency for the Summer about a Design Plan of Standard Duck House using CFD
/ A3EL
(2015) Àü»êÀ¯Ã¼¿ªÇÐÀ» ÀÌ¿ëÇÑ Ç¥ÁØ ¿À¸®»ç ¼³°è¾È¿¡ ´ëÇÑ ÇÏÀý±â ȯ±âÈ¿À² ºÐ¼® Analysis of Ventilation Efficiency for the Summer about a Design Plan of Standard Duck House using CFD ÇÐȸÁö: Çѱ¹³ó°øÇÐȸ³í¹®Áý 57(5) 51 - 60 ÂÊ ÀúÀÚ: ¿©¿íÇö, Á¶¿¹½½, ±Ç°æ¼®, ÇÏÅÂȯ, ¹Ú¼¼ÁØ, ±è¶ô¿ì, ÀÌ»ó¿¬, À̽Â..