¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹³»ÇмúÁö³í¹®

Á¦¸ñ
(2015) Analysis of Ventilation Efficiency for the Summer about a Design Plan of Standard Duck House using CFD
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
153


(2015) Àü»êÀ¯Ã¼¿ªÇÐÀ» ÀÌ¿ëÇÑ Ç¥ÁØ ¿À¸®»ç ¼³°è¾È¿¡ ´ëÇÑ ÇÏÀý±â ȯ±âÈ¿À² ºÐ¼®
Analysis of Ventilation Efficiency for the Summer about a Design Plan of Standard Duck House using CFD


ÇÐȸÁö: Çѱ¹³ó°øÇÐȸ³í¹®Áý 57(5) 51 - 60 ÂÊ


ÀúÀÚ: ¿©¿íÇö, Á¶¿¹½½, ±Ç°æ¼®, ÇÏÅÂȯ, ¹Ú¼¼ÁØ, ±è¶ô¿ì, ÀÌ»ó¿¬, À̽³ë, ÀÌÀκ¹, ¼­ÀÏȯ


°³¿ä

In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER (min-1). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.
 

 
 
Download Link :
https://www.researchgate.net/profile/I-B_Lee/publication/283662739_Analysis_on_Ventilation_Efficiency_of_Standard_Duck_House_using_Computational_Fluid_Dynamics/links/5646d6e408ae9f9c13e787f4.pdf
 
http://www.koreascience.or.kr/article/ArticleFullRecord.jsp?cn=NGHHCI_2015_v57n5_51
 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2016) Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation
/ A3EL
(2016) °Ç¹°¿¡³ÊÁö½Ã¹Ä·¹À̼ÇÀ» È°¿ëÇÑ ¿¬µ¿Çü ¿Â½Ç ¹× ÀÛ¹°¿¡³ÊÁö¸ðµ¨ ¼³°è ¹× ÀÌÀÇ ³Ã·³­¹æºÎÇÏ »êÁ¤ Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation ÇÐȸÁö: ½Ã¼³¿ø¿¹·..
ÀÌÀü±Û
(2015) Measurement of Dust Concentration in a Naturally Ventilated Broiler House according to Season and Worker's Access
/ A3EL
(2015) À©Ä¡Ä¿Æ°½Ä °è»çÀÇ ½Ã±â ¹× ÀÛ¾÷ÀÚ ÃâÀÔ¿¡ µû¸¥ ºÐÁø ¹ß»ý ³óµµ ÃøÁ¤ ¿¬±¸ Measurement of Dust Concentration in a Naturally Ventilated Broiler House according to Season and Worker's Access ÇÐȸÁö: Çѱ¹³ó°øÇÐȸ³í¹®Áý 57(6) 35 - 46 ÂÊ ÀúÀÚ: Á¶¿¹½½, ±Ç°æ¼®, ÀÌÀκ¹, ÇÏÅÂȯ, ¹Ú¼¼ÁØ, ±è¶ô¿ì..