¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹Á¦ÇмúÁö³í¹®

Á¦¸ñ
(2007) CFD modeling to improve the design of a fog system for cooling greenhouses
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
78


(2007) CFD modeling to improve the design of a fog system for cooling greenhouses
 
Journal: JARQ 41 (4), pp.283 – 290.
 
Author: Keesung KIM, Gene A. GIACOMELII, Jeong-Yeol YOON, Sadanori SASE, Jung-Eek SON, Sang-Woon NAM and In-Bok LEE
 
Abstract
A CFD model was developed to simulate the air temperature and relative humidity distribution in greenhouses adopting fog-cooling systems using FLUENT. The developed model was validated using the data from a fog-cooling experiment in a single-span greenhouse without plants. The measured and simulated air temperatures varied from 0.1 to 1.4ºC and the differences of relative humidity varied 0.3– 6.0%. The validated model was then used to evaluate the design of a fog-cooling system in a multi-span glasshouse. The optimal system design was determined in terms of the cooling efficiency and the special uniformity of air temperature and relative humidity. The simulations demonstrated that the best performance of the cooling system occurred when the fog nozzles were located at the height of 2.3 m above the floor and at a distance of 1.9 m from the sidewalls with uniform row-to-row spacing of 3.7 m. The most effective location of the nozzles was within the air entry from the sidewall ventilator inlets of the greenhouse. However, it was important not to wet the sidewalls with the fog. This study suggested that the CFD model developed could be a useful tool to design and evaluate the fog-cooling systems in greenhouses with various configurations.



Keywords: Agricultural facilities, CFD, fog-cooling system, glasshouse, natural ventilation, wind speed.


Download Link :

https://www.jstage.jst.go.jp/article/jarq/41/4/41_283/_article/-char/ja/
 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2007) Evaluation of CFD accuracy for the ventilation study of a naturally ventilated broiler house
/ A3EL
(2007) Evaluation of CFD accuracy for the ventilation study of a naturally ventilated broiler house Journal:JARQ 41 (1), pp.53–64. Author:In-Bok LEE, Sadanori SASE and Si-Heung SUNG Abstract Using the CFD model, a new ventilation system design will be found later taking into consider..
ÀÌÀü±Û
(2006) Study on Ventilation Efficiencies of Naturally- Ventilated Multi-Span Greenhouses in Korea
/ A3EL
(2006)Study on Ventilation Efficiencies of Naturally- Ventilated Multi-Span Greenhouses in Korea Journal:An ASABE Meeting Presentation 064125 Author:In-Bok LEE, Se Woon Hong, Pyoung Wuck Chang, Hyun Seop Hwang, Il Hwan Seo, Sung Yong Lee Abstract In this study, ventilation efficiencies..