¹Ù·Î°¡±â ¸Þ´º

¹Ù·Î°¡±â ¸Þ´º º»¹®³»¿ë ¹Ù·Î°¡±â ¸ÞÀθ޴º ¹Ù·Î°¡±â

ÁÖ¿ä¾È³»

HOME »çÀÌÆ®¸Ê ENGLISH

FONT SIZE

ÆùƮũ±â Å°¿ò 100% 110% 120% 130% 140% ÆùƮũ±â ÁÙÀÓ
¸Þ´ºº¸±â

±¹³»ÇмúÁö³í¹®

Á¦¸ñ
(2014) Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation
ÀÛ¼ºÀÏ
2022-01-10
Á¶È¸¼ö
140


(2014) CFD °ËÁõÀ» À§ÇÑ Ç³µ¿ ¹× PIV¸¦ ÀÌ¿ëÇÑ ÀÚ¿¬È¯±â½Ä ¿Â½Ç ³»ºÎ °ø±âÀ¯µ¿ ºÐ¼®
Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using
Wind Tunnel and PIV for CFD Validation


ÇÐȸÁö: Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ 23(4) 392 - 401 ÂÊ


ÀúÀÚ: ÇÏÁ¤¼ö, ÀÌÀκ¹, ±Ç°æ¼®, ÇÏÅÂȯ


°³¿ä

 The number of large scale greenhouses has recently been increasing to cope with mass consumption of
agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from 1m·s−1 to 1.5m·s−1, air velocities inside the greenhouse
which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

 
 
Download Link :
https://www.researchgate.net/profile/I-B_Lee/publication/272427269_Analysis_on_Internal_Airflow_of_a_Naturally_Ventilated_Greenhouse_using_Wind_Tunnel_and_PIV_for_CFD_
Validation/links/5718463708aed8a339e5b58a/Analysis-on-Internal-Airflow-of-a-Naturally-Ventilated-Greenhouse-using-Wind-Tunnel-and-PIV-for-CFD-Validation.pdf



 
÷ºÎÆÄÀÏ:
÷ºÎÆÄÀÏÀÌ ¾ø½À´Ï´Ù.
´ÙÀ½±Û
(2014) Estimation of Wind Pressure Coefficients on Even-Span Greenhouse Built in Reclaimed Land according to Roof Slop using Wind Tunnel
/ A3EL
(2014) dzµ¿À» ÀÌ¿ëÇÑ °£Ã´Áö ³» ¾çÁöºØÇü ¿Â½ÇÀÇ ÁöºØ °æ»ç¿¡ µû¸¥ dz¾Ð°è¼ö Æò°¡ Estimation of Wind Pressure Coefficients on Even-Span Greenhouse Built in Reclaimed Land according to Roof Slop using Wind Tunnel ÇÐȸÁö: Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ 23(4) 269 - 280 ÂÊ ÀúÀÚ: ±è¶ô¿ì, ±èµ¿¿ì, ·ù±âö, ±Ç..
ÀÌÀü±Û
(2014) Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds
/ A3EL
(2014) °­Á¦È¯±â½Ä °è»çÀÇ °ø±â Áß ºÐÁø ³óµµ ÃøÁ¤ ¹× ¹Ù´ÚÀç·ÎºÎÅÍÀÇ ºÐÁø ¹ß»ý·® ºÐ¼® Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds ÇÐȸÁö: Çѱ¹³ó°øÇÐȸ³í¹®Áý 56(6) 31 - 43 ÂÊ ÀúÀÚ: ±Ç°æ¼®, Á¶¿¹½½, ÀÌÀκ¹, ÇÏÅÂȯ,..